| Characteristics |
| |
| Storage Humidity Range: ≤95%. |
| Short Circuit Protection: Automatic Recovery. |
| Operating Temperature Range: -40°C to +85°C. |
| Storage Temperature Range: -55°C to +125°C. |
| Temperature Rise at Full Load: 80°C (Max.) |
| Lead Temperature: 300°C (1.5mm from case for 10 seconds). |
| Isolation Voltage: 1500VDC (Test for 1 minute and 1mA max.) |
| Isolation Resistance: 1000MW min. (Test at 500VDC) |
| Isolation Capacitance: 1000pF typ. at 100kHz/0.1V. |
| Switching Frequency: 350kHz typ. |
| Cooling: Free air convection. |
| Case Material: Nickle-coated copper (six-sided) |
| MTBF: >1,000,000 hours. |
| Miscellaneous: RoHS Compliant. |
| |
| Item |
Test Condition |
Min |
Typ |
Max |
Units |
| Output Power |
- |
- |
- |
30 |
W |
| Output voltage accuracy |
Refer to Recommended Circuit |
- |
±1 |
±3 |
% |
| Load Regulation |
From 10% to 100% load Nominal Input |
- - |
±0.5 |
±1 |
% |
| Line Regulation |
Inupt Voltage from low to high 100% load |
- - |
±0.2 |
±0.5 |
% |
| Ripple and Noise |
20MHz Bandwidth |
- |
50 |
120 |
mV |
Transistent Recovery Time Transistent Peak Deciation |
25% - 50% - 25% load or 50% - 75% - 50% load step change |
- - |
200 - |
500 ±5 |
µs % |
| Over Current Protection |
Input Voltage Range |
- |
130 |
150 |
% |
| Short Circuit Protection |
Input Voltage Range |
Hiccup, automatic recovery |
| Over Voltage Protection |
3.3V output 5V output 12V output 15V output |
- - - - |
3.9 6.2 15 18
|
- - - - |
VDC |
| Temperature Drift (Vout) |
- |
- |
±0.02 |
- |
%/°C |
| Trim |
- |
- |
±10%Vo |
- |
VDC |
| Note: All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output unless otherwise specified. |